-40%

Fluke 805 FC Mechanical Machine Vibration Meter Tester

$ 948.26

Availability: 32 in stock
  • Brand: Fluke
  • Condition: Mint Condition Manufactory Refurbished
  • MPN: 805

    Description

    This item was sent back to Fluke because of the RTC coin cell is drained. Also the Firmware was updated to 3.0.5. This item is in Mint condition. Please view all photos for content.  Fluke 805 Vibration Meter mechanical troubleshooting and maintenance F805
    The Reliable, Repeatable, Accurate Way to Check Bearings and Overall Vibration
    Make go or no-go maintenance decisions with confidence. The Fluke 805 Vibration Meter is the most reliable vibration screening device available for frontline mechanical troubleshooting teams that need repeatable, severity-scaled readings of overall vibration and bearing condition.
    What Makes the 805 the Best Choice?
    A meter – not a pen – that measures overall vibration as well as specific variables like bearing condition and temperature, to provide a more complete picture
    A combination vibration and force sensor tip that compensates for user variance (force or angle) yielding accurate, repeatable readings
    A four-level severity scale and onboard processor calculate bearing condition and overall vibration using easy-to-understand textual alerts (Good, Satisfactory, Unsatisfactory, Unacceptable)
    Sensor sensitivity can read a wide range of frequencies (10 to 1,000 Hz and 4,000 to 20,000 Hz) covering most machine and component types
    Straight-forward user interface that minimizes the user inputs to RPM range and equipment type
    Features and Benefits
    Innovative sensor design helps minimize measurement variations caused by device angle or contact pressure
    Consistent data quality at both low and high frequency ranges
    Four-level scale indicates severity of problems for overall vibration and bearing condition
    Exportable data via USB
    Trending in Microsoft® Excel using built-in templates
    Overall vibration measurement (10 Hz to 1,000 Hz) for acceleration, velocity and displacement units of measurement for a wide variety of machines
    Crest Factor+ provides reliable bearing assessment using direct sensor tip measurements between 4,000 Hz and 20,000 Hz
    Colored lighting system (green, red) and on-screen comments indicate how much pressure needs to be applied to take measurements
    Temperature measurement with Infrared Temperature Sensor increases diagnostic capabilities
    On-board memory holds up to 3,500 measurements
    Audio output for listening to bearing tones directly
    External accelerometer support for hard to reach locations
    Flashlight for viewing measurement locations in dark areas
    Large screen with high resolution for easy navigation and viewing
    Use the 805 to check the following machine categories:
    Chillers (refrigeration)
    Fans
    Cooling tower drives
    Centrifugal pumps
    Positive displacement pumps
    Air compressors
    Blowers
    Generic gearboxes (rolling element bearings)
    Machine tools (motor, gearboxes, spindles, etc.)
    What is Crest Factor+?
    Crest Factor+ is a new proprietary algorithm (or technology) that takes the confusion out of bearing assessment. The original Crest Factor is used by vibration analysts to identify bearing faults. It is defined as the ratio of the
    peak value/RMS value of a time domain vibration signal.
    A key limitation of the original Crest Factor algorithm is that it does not increase linearly as the bearing degrades, making it very difficult to determine the severity of mechanical issues. In fact, the Crest Factor can actually decrease as a bearing nears catastrophic failure due to large RMS values.
    In order to overcome this limitation, Fluke uses a proprietary algorithm known as Crest Factor+ (CF+). CF+ values range from 1 to 16. As the bearing condition worsens, the CF+ value increases, ensuring the user is easily able to recognize the severity of the problem. To make things even simpler, Fluke has also included a four-level severity scale that identifies the bearing health as Good, Satisfactory, Unsatisfactory or Unacceptable.
    Exporting and trending with the 805
    Trending, or repeated vibration measurements kept in a spreadsheet over time, is the best method to track machine health. With 805 you can easily:
    Export your result to Excel through USB connection
    Trend the readings with the pre-built Microsoft® Excel templates and plot graphs
    Compare the overall vibration readings to ISO Standards
    (10816-1, 10816-3, 10816-7)
    Vibration Meter
    Low Frequency Range (Overall Measurement)
    10 Hz to 1,000 Hz
    High Frequency Range (CF+ Measurement)
    4,000 Hz to 20,000 Hz
    Severity Levels
    Good, satisfactory, unsatisfactory, unacceptable
    Vibration Limit
    50 g peak (100 g peak-peak)
    A/D Converter
    16-bit
    Signal To Noise Ratio
    80 dB
    Sampling Rate
    Low frequency
    20,000 Hz
    High frequency
    80,000 Hz
    Real Time Clock Backup
    Coin battery
    Sensor
    Sensitivity
    100 mV g ± 10%
    Measurement Range
    0.01 g to 50 g
    Low Frequency Range (Overall Measurement)
    10 Hz to 1,000 Hz
    High Frequency Range
    4,000 Hz to 20,000 Hz
    Resolution
    0.01 g
    Accuracy
    At 100 Hz ± 5% of measured value
    Amplitude Units
    Acceleration
    g, m/sec²
    Velocity
    in/sec, mm/sec
    Displacement
    mils, mm
    Infrared Thermometer (Temperature Measurement)
    Range
    -20 °C to 200 °C (-4 °F to 392 °F)
    Accuracy
    ±2 °C (4 °F)
    Focal Length
    Fixed, at ~3.8 cm (1.5")
    External Sensor
    Note: Fluke supports but does not provide external sensors
    Frequency Range
    10 Hz to 1,000 Hz
    Bias Voltage (To Supply Power)
    20 V dc to 22 V dc
    Bias current (To Supply Power)
    Maximum 5 mA
    Firmware
    External Interfaces
    USB 2.0 (full speed) communication
    Data Capacity
    Database on internal flash memory
    Upgrade
    Through USB
    Memory
    Up to 3,500 measurements
    Radiated Emission
    Electrostatic Discharge: Burst
    Standard EN 61000-4-2
    Electromagnetic Interference
    Standard EN 61000-4-3
    RE
    Standard CISPR 11, Class A
    Environmental
    Operating Temperature
    -20 °C to 50 °C (-4 °F to 122 °F)
    Storage Temperature
    -30 °C to 80 °C (-22 °F to 176 °F)
    Operating Humidity
    10% to 95% RH
    (non-condensing)
    Operating/Storage Altitude
    Sea level to 3,048 meters (10,000 feet)
    IP Rating
    IP54
    Vibration Limit
    500g peak
    Drop Test
    1 meter
    General Specifications
    Battery Type
    AA (2) Lithium Iron Disulfide
    Battery Life
    250 measurements
    Size (L x W x H)
    24.1 cm x 7.1 cm x 5.8 cm
    (9.5 in x 2.8 in x 2.3 in)
    Weight
    0.40 kg (0.89 lb)
    Connectors
    USB mini-B 7-pin, stereo audio output jack (3.5 mm Audio Plug), external sensor jack (SMB connector)