"Balanset-1A" excluding accessories. only measuring unit sensors and software

$ 811

Availability: 60 in stock
  • Brand: Vibromera
  • Condition: New

    Description

    Portable field balancer "Balanset-1A"
    1. Introduction
    Balanset-1A is portable dynamic balancer used to balance rigid rotors in their own bearings (in-situ) or as measuring system in the balancing machines. It provide single- and two-plane dynamic balancing services for fans, grinding wheels, spindles, crushers, pumps and other rotating machinery. Balancing software provides the correct balancing solution for single-plane and two-plane balancing automatically.
    Balanset-1A is simple to use for non-vibration experts.
    Balancing procedure uses 3-run method with adding the test mass in every place of balancing (Influence Coefficient Method). Software calculate balancing weghts and place (angle) automatically, show it in the result table and save in archive file. Also you can print balancing report. Waveform and spectrum of vibration charts are possible.
    Balanset-1A includes:
    1 - Interface unit
    2 - two vibration sensors
    3 - optical sensor (laser tachometer)
    5 - Software ( notebook not included - supplied by additional order)
    Specifications:
    2x vibration sensors (vibro accelerometers, cable length 4m, 10m optionally).
    1 x optical sensor (laser tachometer, distance: 50 to 500mm, cable length 4m, 10m optionally)
    1 x USB interface module with software for PC connection
    Software provides measuring vibration, phase angle, calculation of value and angle of correcting mass.
    Details:
    Amplitude vibration range 0.05-100 mm/sec
    Vibration frequency range 5 - 300 Hz
    Accuracy - 5% of full scale
    Correction planes 1 or 2
    Rotation speed measuring 150-60000   rpm
    Phase angle measurement accuracy +-1 degree
    Power  -  140- 220VAC 50Hz
    Weigh - 4 KG
    2. Prepare to work. Software and hardware setup for two-plane balancing.
    2.1  Driver installation
    Install drivers and Balanset-1A software from installation flash disk.
    Insert USB cable to computer USB port. Interface module supplied from USB port.
    Use
    shortcut to run the program.
    2.2  Sensor installation
    Install sensors as shown  on the fig. 1,2,3
    Connect cables
    - vibration sensors to connectors X1 and X2
    - phase laser sensor to connector X3
    fig.1 Two-plane balancing scheme
    Install reflector mark on the rotor and check RPM value on the phase sensor when rotor rotate.
    fig.2  Phase sensor settings
    3. Balancing procedure
    fig.3 Main window for two-plane balancing
    After sensors install click on "F7 - Balancing" button and set balancing parameters. Then click "F9-Next"
    fig.4 Balansing settings
    Then make step-by-step operations as shown in the Table 1 below.
    Table 1. Step-by-step operations
    Run 0 - Start-up without test weight.
    2. Run the machine at its operating speed (be sure that operating  speed is far from resonance frequency of construction)
    3. Click on F9-Start and measure  the vibration  level and  phase angle  in turn without test weight.
    Duration of the measuring process  may amounts  2-10 sec.
    fig.7 Two plane balancing window. Original vibration
    Run 1 - Test weight in plane 1
    4. Stop the  machine  and mount a test weight of suitable  size  arbitrarily in plane 1.
    5. Start up the  machine, click on
    F9-Run
    and measure the new vibration level and phase angle. Duration of the measuring process may amounts  2-10 sec.
    6. Stop  the machine and
    remove the  test  weight
    fig.8 Two plane balancing. Vibration after balancing
    Run 2 - Test weight in plane 2
    7. Mount a trial weight of  suitable size in plane 2 .
    8. Start  the  machine again, click on
    F9-Run
    and measure the vibration level and phase angle once more.
    9. Stop  the machine and
    remove  the  test  weight
    fig.9 Two plane balancing. Vibration after trim balancing
    Step 4 - Calculation
    10. The values of the correction weights  and angles required will be calculated automatically and shown in popup form.
    fig.5 Two plane balancing. Correction weights calculation
    fig.6 Two plane balancing. Correction weight mounting
    RunC
    11. Mount the correction (balance) weights  at the  positions   indicated  in popup form  at the same radius   as the  test (trial) weights (as shown in the figure in right column).
    12. Start up  the  machine  again and   measure the  amount of residual  unbalance in  the rotor , to see how  successful  the  balancing  job has been .
    After balancing you can save influence coefficient balancing (F8- coefficients) and other information (F9- Add to archive) and use it later. (see 4.3, 4.4)
    Balancing procedure - video.
    Field balancing
    4. Other features
    4.1 Vibrometer mode.
    To select Vibrometer mode click "F5- Vibrometer" button in the main window for two-(one-) plane balancing
    To start the measuring process click "F9-Run"
    V1s (V2s) - summary vibration in plane 1(2) (mean-square) V1o (V2o) -  vibration in plane 1(2) (first "revolution" harmonic value) In the right side you can see spectrum window.
    Measuring data files can be saved in archive.
    4.2 Influence coefficients
    If you save the results of previous balance runs, you can eliminate the test weight run and balance the machine using its saved coefficients.  Select "Secondary" in the "Type of balancing" window and click "F2 Select" button to choose previous machine type from list.
    To save coefficients after balancing click "F8-coefficients" in the balancing result pop-up window (see Tab.1) and then click "F9-Save" button. Input machine type ("Name") and other information in the table.
    4.3 Archives and reports.
    To save  balancing information click"F9- Add" to archive in the balancing result pop-up window (see Tab.1). Input machine type ("Name") and other information in the table.
    To open previous saved archives  click "F6-Report" in the main window.
    To print report click "F9-Report"
    Two planes balancing archive.
    4.4 Charts
    To view charts of vibration click on "F8-Diagrams"
    Three kinds of charts are available "Common vibration","Vibration on rotor revolution frequency 1x vibration" and "Spectrum" (for example, for 3000 rev\min frequency is equal 50Hz)
    Common vibration chart
    1x vibration chart.
    Vibration spectrum charts.