-40%
[USED] Bently Nevada TK-3E Vibration Calibrator + NIST Traceable Calibration
$ 1399.2
- Description
- Size Guide
Description
Item DetailsBently Nevada TK-3E
Vibration Calibrator
Click to Enlarge
zoom_in
({IF["[{PRODUCT_IMAGE2}]"!=""]})
({ENDIF}) ({IF["[{PRODUCT_IMAGE3}]"!=""]})
({ENDIF})
NIST Calibration Certificate included with purchase!
[{PRODUCT_LISTING_TITLE}]
({IF["[{PRODUCT_PROPERTY_TAB1_TITLE}]"!=""]})
Features
Light weight and portable
Maintenance-free electric drive powered
Industrial-strength case dramatically improves durability and better protects the precision devices inside
Detachable spindle micrometer with magnetic base
Allows users to carry only the micrometer to the probe location rather than the entire test kit
Universal probe mount accommodates probe diameters from 5 to 19mm
Eliminating the need for multiple adapter collars
({ENDIF}) ({IF["[{PRODUCT_PROPERTY_TAB2_TITLE}]"!=""]})
Included
User Manual
Power Cord
NIST Calibration Certificate
Swing Arm Assembly
Spindle Micrometer
({ENDIF}) ({IF["[{PRODUCT_PROPERTY_TAB3_TITLE}]"!=""]})
Overview
Bently Nevada TK-3E
Vibration Calibrator
The TK-3 Proximity System Test Kit simulates shaft vibration and position for calibrating Bently Nevada monitors. It verifies the operating condition of the monitor readouts as well as the condition of the proximity transducer system. A properly calibrated system ensures that the transducer inputs and the resulting monitor readings are accurate.
The TK-3 uses a removable spindle micrometer assembly to check the transducer system and position monitor calibration. This assembly features a universal probe mount that will accommodate probe diameters from 5 mm to 19 mm (0.197 in to 0.75 in). The mount holds the probe while the user moves the target toward or away from the probe tip in calibrated increments and records the output from the Proximitor* Sensor using a voltmeter. The spindle micrometer assembly also features a convenient magnetic base for ease of use in the field.
Vibration monitors are calibrated using the motor-driven wobble plate. A swing-arm assembly located over the wobble plate holds the proximity probe in place. This assembly uses a universal probe mount, identical to that used with the spindle micrometer assembly. By using the absolute scale factor of the proximity probe in conjunction with a multimeter, the user adjusts the probe to find a position where the desired amount of mechanical vibration (as determined by peak-to-peak DC voltage output) is present. No oscilloscope is needed.
The user can then compare a vibration monitor’s reading to the known mechanical vibration signal input viewed by the proximity probe. The mechanical vibration signal from the TK-3 can range from 50 to 254 μm (2 to 10 mils) peak-to-peak.
({IF["[{PRODUCT_PROPERTY_TAB4_TITLE}]"!=""]})
Shipping
Domestic Shipping
Unless otherwise noted, all shipments are done through UPS. You have the option to select Ground or Expedited service on the listing page. If you would like to utilize your preferred shipping account, please notify us prior to checkout.
International Buyers
TDS will not ship to a delivery location outside of the US. TDS can ship to a customs broker or freight forwarder of your choice. TDS will not be responsible for providing the correct documentation OR scheduling a pickup. Buyer is responsible for all cost and associated fees for shipment including customs fees, taxes, or any other charges associated with shipping, customs, or insurance.
({ENDIF}) ({IF["[{PRODUCT_PROPERTY_TAB5_TITLE}]"!=""]})
Payments
PayPal is our preferred payment method. However, we do accept the additional payment methods listed below.
Once payment is received, confirmed, and eligible for Seller Protection, the items purchased will be immediately processed through the calibration/certification process and dispatched for shipping.
Payment confirmations received after 4:00 PM CST may not be able to ship until the following business day. If this is the case, the buyer will be informed promptly.
Payment must be received within 3 business days of asset being sold. If buyer does not notify seller on or before that time, asset will be re-listed and purchase cancelled.
({ENDIF}) ({IF["[{PRODUCT_PROPERTY_TAB6_TITLE}]"!=""]})
Returns
30-Day Returns Accepted
We strive to exceed our customer's expectation and maintain 100% positive feedback. Please contact us immediately if you are not completely satisfied with your purchase
Returns must be requested within 30 days of delivery. Item must be returned within 5 days of return request. Buyer will NOT receive a refund/replacement until the unwanted equipment is returned and received in it's original packaging and condition. Buyer is responsible for any and all return shipping costs unless otherwise stated.
Please note that returning merchandise with significant signs of use or damage by the buyer may result in a partial refund.
Unless otherwise stated in the listing, your item will undergo a NIST traceable calibration prior to shipment. This service is offered at no additional expense to the buyer as a courtesy to ensure the item(s) received meet your expectations. In addition, your item will pass through our QA process, overseen by qualified equipment managers and logistics coordinators. This process includes the following service:
NIST traceable calibration service (certificate provided with purchase) to guarantee the asset meets manufacturer specifications.
Quality Inspection: Performed to ensure necessary documentation and accessories are present.
Function Test: An operational performance test executed post-calibration an pre-packaging to ensure equipment functionality and operation
({ENDIF})